Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 14.443
Filtrar
1.
BMC Musculoskelet Disord ; 25(1): 277, 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38600536

RESUMEN

INTRODUCTION: The number of primary and revision Total Knee Arthroplasty (TKA) cases are expected to increase in future. There are various advantages and disadvantage to employing either of the two main types of stem fixation methods - cemented or hybrid technique. This review aimed to study the most optimal fixation method for revision TKAs by comparing radiological outcomes and re-revision rates. METHODS: A systematic review and meta-analysis was performed using PubMed and Cochrane Library from 2010 to identify studies explicitly comparing outcomes between cemented against hybrid fixation revision TKA techniques, with a minimum follow up of at least 24 months. A total of 8 studies was included in this review. Egger's test and visual inspection of the funnel plot did not reveal publication bias. RESULTS: There was no statistically significant difference in radiological failure and loosening (OR 0.79, CI 0.37-1.66, I2 = 29%, p = 0.22), all causes of re-revision (OR 1.03, CI 0.73-1.44, I2 = 0%, p = 0.56) and aseptic revision (OR 0.74, CI 0.27-2.02, I2 = 0%, p = 0.41) between cemented and hybrid techniques. Functional and pain outcomes compared between the two fixation techniques were largely similar across the studies included in this meta-analysis. CONCLUSION: Despite a trend favouring hybrid stems in revision TKA, current evidence revealed that radiological outcomes and re-revision rates are largely similar between cemented and hybrid fixation techniques.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Cementos para Huesos/uso terapéutico , Examen Físico , Diseño de Prótesis , Falla de Prótesis , Reoperación/métodos , Resultado del Tratamiento
2.
Clin Orthop Surg ; 16(2): 242-250, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38562632

RESUMEN

Background: During total knee arthroplasty (TKA), patellar retention is performed when the cartilage is fairly well preserved and the thickness of the patella is relatively thin. However, clinical outcomes of the non-resurfaced patella in TKA according to the cartilage status are lacking in the literature. The purpose of this study was to compare patient-reported outcome measures (PROMs) according to the grade and location of the patellar cartilage lesion in TKA patients. Methods: The outcomes of 165 osteoarthritis patients (186 knees) who underwent cemented mobile-bearing TKA without patellar resurfacing were assessed and classified according to the grade and location of the patellar cartilage lesion. PROMs using the Western Ontario and MacMaster Universities Osteoarthritis index, the Knee Society Score (Knee Society Function Score and Knee Society Knee Score), and the Hospital for Special Surgery score were evaluated preoperatively and at postoperative 2, 4, 6, and 8 years. The correlations between PROMs and the grade and location of the cartilage lesion were assessed. Additionally, radiologic outcomes including the patellar tilt angle and patellar height were assessed and their correlation with the grade of cartilage lesion was analyzed. Analysis of variance was used to determine statistical significance. Results: There was no significant difference between PROMs according to the grades and locations of cartilage lesions at any postoperative follow-up. Radiologic parameters also showed no significant differences according to the grades of patellar cartilage lesions. Conclusions: The grade and location of the patellar cartilage lesion had no influence on clinical outcomes in mobile-bearing TKA with patellar retention at short- and long-term follow-up.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Rótula/diagnóstico por imagen , Rótula/cirugía , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/cirugía , Cartílago/cirugía , Periodo Posoperatorio , Resultado del Tratamiento , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía
3.
Clin Orthop Surg ; 16(2): 251-258, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38562641

RESUMEN

Background: The purpose of this study was to evaluate the clinical and radiological outcomes of high-flexion total knee arthroplasty (TKA) using Vega Knee System (B. Braun, Aesculap) at a long-term follow-up and to analyze the implant survivorship. Methods: We enrolled 165 patients (232 knees) with a minimum 7-year follow-up after TKA (VEGA Knee System). For clinical assessment, range of motion (ROM), Knee Injury and Osteoarthritis Outcome Score (KOOS), and Western Ontario and McMaster University Osteoarthritis Index (WOMAC) were used. For radiologic assessment, hip-knee-ankle angle, component position, and the existence of radiolucent lines and loosening were used. Survival analysis was conducted using the Kaplan-Meier method. Results: The mean follow-up period was 9.8 years. The mean ROM increased from 124.4° to 131.4° at the final follow-up. The WOMAC score decreased from 38.5 to 17.4 at the final follow-up (p < 0.001). All 5 subscales of the KOOS improved at the final follow-up (all subscales, p < 0.001). Revision TKA was performed in 10 cases (4.3%), which included 9 cases of aseptic loosing and 1 case of periprostatic joint infection. Of the 9 aseptic loosening cases (3.9%), 8 cases (3.4%) were loosening of the femoral component and 1 case (0.4%) was loosening of the tibial component. When revision for any reason was considered an endpoint, the 10-year survivorship was 96.2% (95% confidence interval [CI], 93.9%-98.5%). On the other hand, when revision for aseptic loosening was considered the endpoint, the 10-year survivorship was 96.6% (95% CI, 94.4%-98.8%). Conclusions: The Vega Knee System provided good clinical results in the long-term follow-up period. Although the VEGA Knee System showed acceptable implant survivorship, loosening of the femoral component occurred in about 3.4% of the patients. For more accurate evaluation of the survivorship of high-flexion design TKA with a short posterior flange, it is necessary to conduct more long-term follow-up studies targeting diverse races, especially Asians who frequently perform high-flexion activities.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Falla de Prótesis , Resultado del Tratamiento , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Osteoartritis/cirugía , Reoperación , Rango del Movimiento Articular , Diseño de Prótesis , Estudios de Seguimiento , Estudios Retrospectivos
4.
Acta Ortop Mex ; 38(1): 15-21, 2024.
Artículo en Español | MEDLINE | ID: mdl-38657147

RESUMEN

INTRODUCTION: reconstruction of large bone defects using modular knee arthroplasty (MKA) presents a significant challenge in terms of functionality. The objective of the present work was to identify the different prognostic factors associated with failure of MKA in cancer patients. MATERIAL AND METHODS: a retrospective cohort study was conducted, including patients with a diagnosis of musculoskeletal tumor in the distal femur or proximal tibia, who underwent MKA between January 1, 2010, and December 31, 2021. RESULTS: 49 patients were included, of which 25 (51.02%) were women and 24 (48.98%) men, with a mean age of 29.57 years. Of these, 14 (28.57%) patients experienced some type of MKA failure. The most frequent complication that led to failure was periprosthetic infection, observed in seven (14.29%) patients. Variables associated with MKA failure included biopsies performed outside our hospital (HR 3.2, 95% CI 1.4-6.4, p = 0.02), the length of the long axis of the tumor (HR 2.1, 95% CI 1.2-4.6, p = 0.01) and a prolonged surgical time (HR 3.37, 95% CI 1.1-8.6, p = 0.04). CONCLUSION: the most significant prognostic factors associated with MKA failure in our cohort were tumor size, prolonged surgical time, and performance of the diagnostic biopsy in a center not specialized in the management of this type of patient. These findings highlight the importance of considering these variables to improve outcomes in patients undergoing MKA.


INTRODUCCIÓN: la reconstrucción de grandes defectos óseos mediante artroplastía modular de rodilla (AMR) representa un desafío significativo en términos de funcionalidad. El objetivo del presente trabajo fue identificar los diferentes factores pronósticos asociados al fracaso de la AMR en pacientes oncológicos. MATERIAL Y MÉTODOS: se realizó un estudio de cohorte retrospectiva, incluyendo pacientes con diagnóstico de tumor musculoesquelético en el fémur distal o la tibia proximal, que fueron sometidos a AMR entre el 1 de Enero de 2010 y el 31 de Diciembre de 2021. RESULTADOS: se incluyeron 49 pacientes, de los cuales 25 (51.02%) eran mujeres y 24 (48.98%) hombres, con una edad media de 29.57 años. De éstos, 14 (28.57%) pacientes experimentaron algún tipo de fracaso de la AMR. La complicación más frecuente que condicionó el fracaso fue la infección periprotésica, observada en siete (14.29%) pacientes. Las variables asociadas con el fracaso de las AMR incluyeron biopsias realizadas fuera de nuestro hospital (HR 3.2, IC95% 1.4-6.4, p = 0.02), longitud del eje mayor del tumor (HR 2.1, IC95% 1.2-4.6, p = 0.01) y tiempo quirúrgico prolongado (HR 3.37, IC95% 1.1-8.6, p = 0.04). CONCLUSIÓN: los factores pronósticos asociados al fracaso de las AMR en nuestra cohorte fueron el tamaño del tumor, un tiempo quirúrgico prolongado y la realización de la biopsia diagnóstica en un centro no especializado en el manejo de este tipo de pacientes. Estos hallazgos resaltan la importancia de considerar estas variables en pacientes sometidos a AMR.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Humanos , Masculino , Femenino , Estudios Retrospectivos , Artroplastia de Reemplazo de Rodilla/métodos , Adulto , Pronóstico , Persona de Mediana Edad , Neoplasias Óseas/cirugía , Adulto Joven , Infecciones Relacionadas con Prótesis/etiología , Tempo Operativo , Falla de Prótesis , Tibia/cirugía , Adolescente , Prótesis de la Rodilla , Insuficiencia del Tratamiento
5.
J Orthop Surg (Hong Kong) ; 32(1): 10225536241246326, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38652873

RESUMEN

BACKGROUND: The single-radius design is one of the major total knee arthroplasty (TKA) designs and widely used all over the world. The objective of this study was to compare in vivo kinematics between the anteroposterior (AP) single-radius design with mediolateral (ML) single-radius (Non Restricted Geometry; NRG) and ML dual-radius (Triathlon) during stair activities. METHODS: A total of 21 knees in 18 patients (NRG group: 10 knees in 7 patients, Triathlon group: 11 knees in 11 patients) with a clinically successful posterior stabilized TKA were examined. Under fluoroscopic surveillance, each patient performed stair ascending and descending motions. In vivo kinematics were analyzed using 2D/3D registration technique. The knee flexion angle, rotation angle, varus-valgus angle, AP translation of the femorotibial contact point for both the medial and lateral sides of the knee, and post-cam engagement were evaluated. RESULTS: There were no significant differences between the two groups in rotation angle and AP translation at each flexion angle. Examining the varus-valgus angle, the NRG group showed varus position at an early flexion angle during both stair activities.Post-cam engagement was observed in both groups during both stair activities. The mean flexion angle of engagement in the NRG group, the post of which was located anterior to the Triathlon, was larger than that in the Triathlon group during both stair activities. CONCLUSION: Despite the same AP single-radius TKA, ML single-radius might affect varus motion at an early flexion angle.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Diseño de Prótesis , Rango del Movimiento Articular , Subida de Escaleras , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Fenómenos Biomecánicos , Anciano , Masculino , Femenino , Subida de Escaleras/fisiología , Persona de Mediana Edad , Articulación de la Rodilla/fisiopatología , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Osteoartritis de la Rodilla/fisiopatología , Anciano de 80 o más Años
6.
Medicine (Baltimore) ; 103(14): e37697, 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38579049

RESUMEN

BACKGROUND: Total knee arthroplasty involves the use of cemented tibial components for fixation. In recent years, cementless porous tantalum tibial components have been increasingly utilized. The aim of this meta-analysis was to compare the efficacy of cementless porous tantalum tibial components with traditional cemented tibial components in terms of postoperative outcomes following total knee arthroplasty. METHODS: Relevant literature was retrieved from Cochrane Library, PubMed, Embase, and Web of Science using the search terms "(trabecular metal OR Porous tantalum)" AND "knee" up to July 2023. The weighted mean difference with a 95% confidence interval was used as the effect size measure to evaluate the functional recovery of the knee joint, radiological analysis, complications, and implant revisions between cementless porous tantalum tibial components and traditional cemented tibial components after total knee arthroplasty. Review Manager 5.3 was utilized to conduct a comparative analysis of all included studies. RESULTS: Nine studies with a total of 1117 patients were included in this meta-analysis, consisting of 447 patients in the porous tantalum group and 670 patients in the cemented group. Radiological analysis demonstrated that the porous tantalum group had better outcomes than the cemented group (P < .05). The combined results for the 5-year and 10-year follow-ups, range of motion, Western Ontario and McMaster University Osteoarthritis Index, complications, and implant revisions showed no significant differences between the porous tantalum and cemented groups. CONCLUSION: The results of the 5-year and 10-year follow-ups indicate that the use of cementless porous tantalum tibial components is comparable to traditional cemented tibial components, with no significant advantages observed. However, at the 5-year follow-up, the porous tantalum group demonstrated a good bone density in the proximal tibia. Future studies with a larger sample size, long-term clinical follow-up, and radiological results are needed to verify the differences between the 2 implants.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Tantalio , Tibia/cirugía , Porosidad , Resultado del Tratamiento , Articulación de la Rodilla/cirugía , Diseño de Prótesis , Cementos para Huesos , Osteoartritis de la Rodilla/cirugía
7.
Acta Orthop ; 95: 157-165, 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38597226

RESUMEN

BACKGROUND AND PURPOSE:  Different marker-selection methods are applied to represent implant and tibial segments in radiostereometric analysis (RSA) studies of total knee arthroplasty (TKA). Either a consistent set of markers throughout subsequent RSA examinations ("consistent-marker method") is used or all available markers at each follow-up ("all-marker method"). The aim of this secondary analysis was to compare marker-selection methods on individual and group level TKA migration results. METHODS:  Data from a randomized RSA study with 72 patients was included. Tibial baseplate migration was evaluated at 3 months, 1, 2, and 5 years postoperatively with both marker-selection methods. Additionally, migration was calculated using 5 fictive points, either plotted based on the consistent set of markers or all available markers. RESULTS:  Migration could be calculated with both marker-selection methods for 248 examinations. The same prosthesis and bone markers (n = 136), different prosthesis markers (n = 71), different bone markers (n = 21), or different prosthesis and bone markers (n = 20) were used. The mean difference in maximum total point motion (MTPM) between all examinations was 0.02 mm, 95% confidence interval -0.26 to 0.31 mm. 5 implants were classified as continuously migrating with the consistent-marker method versus 6 implants (same 5 plus one additional implant) with the all-marker method. Using fictive points, fewer implants were classified as continuously migrating in both marker-selection methods. Differences between TKA groups in mean MTPM were comparable with both marker-selection methods, also when fictive points were used. CONCLUSION:  Estimated group differences in mean MTPM were similar between marker-selection methods, but individual migration results differed. The latter has implications when classifying implants for estimated risk of future loosening.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Estudios de Seguimiento , Análisis Radioestereométrico , Falla de Prótesis , Diseño de Prótesis , Osteoartritis de la Rodilla/cirugía
8.
Med Sci Monit ; 30: e942888, 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38576138

RESUMEN

BACKGROUND This retrospective study aimed to compare patient outcomes from standard total knee arthroplasty (TKA) vs navigation-guided arthroplasty using the Brainlab software-guided surgical system at Cangzhou Hospital of Integrated TCM-WM, Hebei, Hebei Province, China from January 2021 to July 2023. MATERIAL AND METHODS A total of 239 patients who underwent total knee arthroplasty in Cangzhou Hospital of Integrated TCM-WM, Hebei from January 2021 to July 2023 were retrospectively analyzed. According to the inclusion criteria, 212 eligible patients were selected for analysis and divided into a Navigation Group (NG) (n=105) and a Traditional Group (TG) (n=107) according to surgical method used. Outcomes measured included duration of disease, operative time, intraoperative blood loss volume, postoperative length of hospital stay, and pain measured by the hospital for special surgery knee score (HSS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC), and forgotten joint score (FJS). RESULTS The comparison of perioperative results between the 2 groups showed that the incision length in the NG was significantly longer than that in the TG (P<0.001, 95% Cl 2.59-3.35). At 3 months after surgery, the HSS score of the NG was statistically higher than that of the TG (P=0.002, 95% Cl 3.42-4.46); the WOMAC score of the NG was lower than that of the TG (P<0.001, 95% Cl -4.41-2.87); and the FJS score of the NG was significantly higher than that of the TG (P=0.003, 95% Cl 2.39-3.67). CONCLUSIONS Compared with conventional TKA, use of the Brainlab navigation system is associated with a longer incision, more accurate implantation position of the prosthesis, faster recovery of knee joint function, and helps patients to "forget" about their knee prosthesis in the short term.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Herida Quirúrgica , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Estudios Retrospectivos , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Resultado del Tratamiento
9.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 68(2): 128-133, Mar-Abr. 2024. tab
Artículo en Español | IBECS | ID: ibc-231891

RESUMEN

Antecedentes y objetivo: Las escalas de valoración de fragilidad no han sido estandarizadas para la evaluación prequirúrgica de pacientes sometidos a un reemplazo total de rodilla (RTR). El objetivo de este estudio fue comparar la eficacia de la escala de valoración de la Sociedad Americana de Anestesiología (ASA), el índice de comorbilidad de Charlson (ICC) y la escala simple de fragilidad (SSF) en la predicción de complicaciones, estancia hospitalaria, reingresos y mortalidad después del RTR electivo. Materiales y métodos: Estudiamos retrospectivamente a 448 pacientes que se sometieron a un RTR por artrosis en nuestra institución entre 2016 y 2019. Estos se dividieron en 2 grupos: grupo A (263 pacientes <80 años) y grupo B (185 pacientes >80 años). Todos fueron clasificados por escalas ASA, ICC y SSF. Resultados: El ICC fue mayor en el grupo B (mediana: 5 [RI: 4-6] vs. 4 [RI: 3-5]; p<0,001); sin embargo, no se asoció con un mayor número de complicaciones. Al realizar un análisis de regresión logística encontramos, para las complicaciones: OR SSF=0,67; ICC=1,11; ASA 3 y 4=0,89 y edad=1,04; mientras que para los reingresos: OR SSF=2,09; ICC=1,01; ASA 3 y 4=0,79 y edad=1. Conclusiones: Las escalas ICC y SSF demostraron no presentar diferencias a la escala ASA en la predicción de reingresos, complicaciones y estancia hospitalaria. Sin embargo, el SSF parece tener una mejor correlación en la predicción de la readmisión no planificada.(AU)


Background and objective: Frailty scores have not been standardized for the preoperative assessment of patients undergoing total knee replacement (TKR). The aim of this study was to compare the efficacy of the American Society of Anesthesiology (ASA) score, the Charlson comorbidity index (ICC) and the simple frailty score (SSF) in predicting complications, hospital stay, readmissions and mortality after elective TKR. Materials and methods: We retrospectively studied 448 patients who underwent TKR for osteoarthritis at our institution between 2016 and 2019. They were divided into two groups: Group A (263 patients, <80 years) and Group B (185 patients, >80 years).). All were classified by ASA, ICC and SSF scores. Results: The ICC was higher in Group B (median 5 [RI: 4-6] vs. 4 [RI: 3-5]; P<.001); however, it was not associated with a higher number of complications. When performing a logistic regression analysis we found, for complications: OR SSF=0.67, ICC=1.11; ASA 3 & 4=0.89 and age=1.04; while for readmissions: OR SSF=2.09; ICC=1.01; ASA 3 & 4=0.79 and age=1. Conclusions: The ICC and SSF scales showed no differences to the ASA scale in the prediction of readmissions, complications and hospital stay. However, the SSF seems to have a better correlation in predicting unplanned readmission.(AU)


Asunto(s)
Humanos , Masculino , Femenino , Anciano de 80 o más Años , Prótesis de la Rodilla , Rodilla/cirugía , Fracturas de Cadera , Tiempo de Internación , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla
10.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 68(2): T128-T133, Mar-Abr. 2024. tab
Artículo en Inglés | IBECS | ID: ibc-231892

RESUMEN

Antecedentes y objetivo: Las escalas de valoración de fragilidad no han sido estandarizadas para la evaluación prequirúrgica de pacientes sometidos a un reemplazo total de rodilla (RTR). El objetivo de este estudio fue comparar la eficacia de la escala de valoración de la Sociedad Americana de Anestesiología (ASA), el índice de comorbilidad de Charlson (ICC) y la escala simple de fragilidad (SSF) en la predicción de complicaciones, estancia hospitalaria, reingresos y mortalidad después del RTR electivo. Materiales y métodos: Estudiamos retrospectivamente a 448 pacientes que se sometieron a un RTR por artrosis en nuestra institución entre 2016 y 2019. Estos se dividieron en 2 grupos: grupo A (263 pacientes <80 años) y grupo B (185 pacientes >80 años). Todos fueron clasificados por escalas ASA, ICC y SSF. Resultados: El ICC fue mayor en el grupo B (mediana: 5 [RI: 4-6] vs. 4 [RI: 3-5]; p<0,001); sin embargo, no se asoció con un mayor número de complicaciones. Al realizar un análisis de regresión logística encontramos, para las complicaciones: OR SSF=0,67; ICC=1,11; ASA 3 y 4=0,89 y edad=1,04; mientras que para los reingresos: OR SSF=2,09; ICC=1,01; ASA 3 y 4=0,79 y edad=1. Conclusiones: Las escalas ICC y SSF demostraron no presentar diferencias a la escala ASA en la predicción de reingresos, complicaciones y estancia hospitalaria. Sin embargo, el SSF parece tener una mejor correlación en la predicción de la readmisión no planificada.(AU)


Background and objective: Frailty scores have not been standardized for the preoperative assessment of patients undergoing total knee replacement (TKR). The aim of this study was to compare the efficacy of the American Society of Anesthesiology (ASA) score, the Charlson comorbidity index (ICC) and the simple frailty score (SSF) in predicting complications, hospital stay, readmissions and mortality after elective TKR. Materials and methods: We retrospectively studied 448 patients who underwent TKR for osteoarthritis at our institution between 2016 and 2019. They were divided into two groups: Group A (263 patients, <80 years) and Group B (185 patients, >80 years).). All were classified by ASA, ICC and SSF scores. Results: The ICC was higher in Group B (median 5 [RI: 4-6] vs. 4 [RI: 3-5]; P<.001); however, it was not associated with a higher number of complications. When performing a logistic regression analysis we found, for complications: OR SSF=0.67, ICC=1.11; ASA 3 & 4=0.89 and age=1.04; while for readmissions: OR SSF=2.09; ICC=1.01; ASA 3 & 4=0.79 and age=1. Conclusions: The ICC and SSF scales showed no differences to the ASA scale in the prediction of readmissions, complications and hospital stay. However, the SSF seems to have a better correlation in predicting unplanned readmission.(AU)


Asunto(s)
Humanos , Masculino , Femenino , Anciano de 80 o más Años , Prótesis de la Rodilla , Rodilla/cirugía , Fracturas de Cadera , Tiempo de Internación , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla
11.
J Med Case Rep ; 18(1): 147, 2024 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-38459591

RESUMEN

BACKGROUND: The transition from revision total knee arthroplasty (RTKA) to arthrodesis involves the replacement of cemented femoral and tibial stems with a modular nail designed for arthrodesis. This conversion process is associated with challenges such as bone loss, blood loss, and prolonged surgical durations. Effectively addressing these complexities through a less invasive surgical approach could be pivotal in enhancing patient outcomes and minimizing associated complications. CASE PRESENTATION: A 75-year-old white Caucasian female patient with a revision total knee arthroplasty (RTKA) performed with a modular uncemented rotating-hinge system, reporting an history of recurrent patellar dislocation, was referred to our institution after a fall resulting in periprosthetic tibial plateau fracture. The fracture was treated with open reduction and internal fixation, but afterwards the patient had been unable to walk again. Tibial stem was mobilized, and extensor mechanism was insufficient due to chronic incomplete quadriceps tendon rupture. The femoral stem was stable, so we decided to convert the rotating-hinge in a arthrodesis with an uncemented modular knee fusion nail maintaining the previous femoral stem. CONCLUSIONS: The result was a successful arthrodesis with minimal bone and blood loss, reduced operative time, and optimal functional outcome at the one-year follow-up. This case highlights the advantage of using a modular knee revision platform system that gives the opportunity to convert a RTKA in arthrodesis.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Femenino , Anciano , Artroplastia de Reemplazo de Rodilla/métodos , Reoperación/métodos , Articulación de la Rodilla/cirugía , Artrodesis/métodos , Estudios Retrospectivos , Resultado del Tratamiento
12.
J Nippon Med Sch ; 91(1): 88-98, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38462443

RESUMEN

BACKGROUND: This study used finite element analysis (FEA) to investigate the effect of varus and valgus angle on the lateral compartment in unicompartmental knee arthroplasty (UKA). METHODS: One patient who underwent UKA was enrolled as the subject. Thirteen working conditions of the femoral prosthesis were simulated at varus and valgus angles of 0°, 2°, 4°, 6°, 8°, 10°, and 12°. A load of 1,000 N was applied downward along the mechanical axis of the femur, and the highest stress values on the surface of the polyethylene liner, cancellous bone under the tibial prosthesis, cartilage of femur lateral condyle, lateral meniscus, and tibial lateral plateau cartilage in each model were recorded. The six highest points were used to calculate the mean value. RESULTS: The highest stress values on the surface of the polyethylene liner, cancellous bone under the tibial prosthesis, cartilage of femur lateral condyle, lateral meniscus, and tibial lateral plateau cartilage increased with an increase in the femoral prosthesis varus/valgus angle. As compared with the standard position of the femoral prosthesis, there was no significant difference in the surface stress values of the polyethylene liner, cancellous bone under the tibial prosthesis, cartilage of femur lateral condyle, lateral meniscus and tibial lateral plateau cartilage when the femoral prosthesis varus/valgus angle was less than 4° (p > 0.05). In addition, the stress magnitude on the polyethylene liner, cancellous bone under the tibial prosthesis, cartilage of femur lateral condyle, lateral meniscus, and tibial lateral plateau cartilage significantly increased when the femoral prosthesis varus/valgus angle was greater than 4° (p < 0.001). CONCLUSIONS: The optimal femoral prosthesis varus/valgus angle in UKA was less than 4°.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Análisis de Elementos Finitos , Fenómenos Biomecánicos , Fémur/cirugía , Polietileno
13.
Can J Surg ; 67(2): E85-E90, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38453351

RESUMEN

BACKGROUND: Interest in cementless total knee arthroplasty (TKA) has increased with advancement of biomaterials and implant design and associated improved longevity. We sought to evaluate the gap patterns and radiolucent zones radiographically for 2 newer-generation cementless TKA designs. METHODS: We retrospectively reviewed our single-institution database between January 2017 and December 2019. We identified patients with a porous keeled tibia base-plate with 4-bullet cruciform spikes and peri-apatite coated femoral component (study group 1) and patients who received a cementless porous coated femoral component and rotating platform tibia baseplate with 4 peripheral porous coated pegs around a central cone (study group 2). We identified gap patterns at 6 weeks and at 1 year or more postoperatively on radiographs, noting indications for reoperation. RESULTS: We identified 228 patients in study group 1 and 41 patients in study group 2. At 1-year follow-up, we found evidence of resolved femoral gaps in 52 (72.2%) of 72 patients in study group 1 and 10 (58.8%) of 17 patients in study group 2 (p = 0.124). We identified 27 (84.3%) of 32 patients in study group 1 and 7 (70.0%) of 10 patients in study group 2 with resolved tibia gaps (p = 0.313). After 1 year, there were significantly more Zone 3a femoral zonal radiolucent gaps (p = 0.001) and Zone 8 tibia zonal radiolucent gaps (p = 0.002) in study group 2 than in study group 1. There were 4 reoperations for study group 1 and 0 reoperations for study group 2. CONCLUSION: The modern cementless TKA systems have varied gap patterns in postoperative radiographs, which may be attributed to the implant design. Most radiolucent gaps resolve radiographically on follow-up.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Estudios de Seguimiento , Estudios Retrospectivos , Fémur/diagnóstico por imagen , Fémur/cirugía , Reoperación , Diseño de Prótesis , Resultado del Tratamiento , Falla de Prótesis
14.
Sensors (Basel) ; 24(5)2024 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-38475232

RESUMEN

Aseptic loosening is the dominant failure mechanism in contemporary knee replacement surgery, but diagnostic techniques are poorly sensitive to the early stages of loosening and poorly specific in delineating aseptic cases from infections. Smart implants have been proposed as a solution, but incorporating components for sensing, powering, processing, and communication increases device cost, size, and risk; hence, minimising onboard instrumentation is desirable. In this study, two wireless, battery-free smart implants were developed that used passive biotelemetry to measure fixation at the implant-cement interface of the tibial components. The sensing system comprised of a piezoelectric transducer and coil, with the transducer affixed to the superior surface of the tibial trays of both partial (PKR) and total knee replacement (TKR) systems. Fixation was measured via pulse-echo responses elicited via a three-coil inductive link. The instrumented systems could detect loss of fixation when the implants were partially debonded (+7.1% PKA, +32.6% TKA, both p < 0.001) and fully debonded in situ (+6.3% PKA, +32.5% TKA, both p < 0.001). Measurements were robust to variations in positioning of the external reader, soft tissue, and the femoral component. With low cost and small form factor, the smart implant concept could be adopted for clinical use, particularly for generating an understanding of uncertain aseptic loosening mechanisms.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Falla de Prótesis , Reoperación/métodos , Tibia/cirugía , Articulación de la Rodilla/cirugía , Diseño de Prótesis
15.
Clin Biomech (Bristol, Avon) ; 114: 106232, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38547571

RESUMEN

BACKGROUND: Unicompartmental knee arthroplasty is an effective treatment for knee osteoarthritis, but it has the risk of failure, and the installation position of the prosthesis is one of the factors affecting the failure. There are few biomechanical studies on the installation angle of unicompartmental knee prosthesis. METHODS: Constructed a finite element model of a normal human knee joint, and the validity of the model was verified by stress and front anterior methods. The mobile-bearing unicompartmental knee arthroplasty femoral prosthesis was placed at 3° intervals from 0° sagittal plane to 15° flexion, and - 2° and 17°were established, and observing the biomechanical changes of components. FINDINGS: Maximum peak stresses occurred at a sagittal mounting angle of -2° for the insert and the contralateral meniscus, with the tibia showing a maximum at 17° sagittal and the tibial prosthesis stress maximum occurring at 6° sagittal. As the sagittal plane angle of the femoral prosthesis increases and the osteotomy distance extends posteriorly, more bone is amputated during the osteotomy. The ratio of the distance from the tip of the anterior intramedullary nail to the anterior end of the osteotomy to the total anteroposterior length of the sagittal osteotomy ranged from 43.2% to 44.6%. INTERPRETATION: In this paper, the more appropriate sagittal mounting position for the femoral prosthesis is between 9 and 12°, based on the amount of osteotomy and the peak stress of each component in a standing position.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Análisis de Elementos Finitos , Fenómenos Biomecánicos , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Tibia/cirugía
16.
Bone Joint J ; 106-B(4): 372-379, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38555938

RESUMEN

Aims: Histology is widely used for diagnosis of persistent infection during reimplantation in two-stage revision hip and knee arthroplasty, although data on its utility remain scarce. Therefore, this study aims to assess the predictive value of permanent sections at reimplantation in relation to reinfection risk, and to compare results of permanent and frozen sections. Methods: We retrospectively collected data from 226 patients (90 hips, 136 knees) with periprosthetic joint infection who underwent two-stage revision between August 2011 and September 2021, with a minimum follow-up of one year. Histology was assessed via the SLIM classification. First, we analyzed whether patients with positive permanent sections at reimplantation had higher reinfection rates than patients with negative histology. Further, we compared permanent and frozen section results, and assessed the influence of anatomical regions (knee versus hip), low- versus high-grade infections, as well as first revision versus multiple prior revisions on the histological result at reimplantation. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), chi-squared tests, and Kaplan-Meier estimates were calculated. Results: Overall, the reinfection rate was 18%. A total of 14 out of 82 patients (17%) with positive permanent sections at reimplantation experienced reinfection, compared to 26 of 144 patients (18%) with negative results (p = 0.996). Neither permanent sections nor fresh frozen sections were significantly associated with reinfection, with a sensitivity of 0.35, specificity of 0.63, PPV of 0.17, NPV of 0.81, and accuracy of 58%. Histology was not significantly associated with reinfection or survival time for any of the analyzed sub-groups. Permanent and frozen section results were in agreement for 91% of cases. Conclusion: Permanent and fresh frozen sections at reimplantation in two-stage revision do not serve as a reliable predictor for reinfection.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Prótesis de Cadera , Prótesis de la Rodilla , Infecciones Relacionadas con Prótesis , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Prótesis de la Rodilla/efectos adversos , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera/efectos adversos , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/cirugía , Estudios Retrospectivos , Reinfección , Articulación de la Rodilla/cirugía , Reoperación/métodos
17.
Knee Surg Sports Traumatol Arthrosc ; 32(4): 915-928, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38426570

RESUMEN

PURPOSE: The relationship between constitutional coronal alignment and implant positioning on trochlear groove restoration in total knee arthroplasty (TKA) is poorly understood. This study aimed to determine whether the choice of alignment philosophy significantly affects the restoration of the trochlea groove. METHODS: Sixty-one imageless robotic TKAs performed by a single orthopaedic surgeon were retrospectively reviewed. In each case, the entire native trochlea was digitized to generate the native femoral anatomy, and implants were planned according to a functional alignment (FA) technique. Final implant position was recorded using the validated bone resection planes from the navigation system. Simulated femoral component positions were generated according to previously described alignment techniques: mechanical alignment (MA), gap balancing (GB), kinematic alignment (KA), restricted kinematic alignment (rKA) and restricted inverse kinematic alignment (riKA). Trochlear angle (TA), trochlear under/overstuffing and mediolateral sulcus offset were compared between the six simulated alignment techniques, as well as the final implanted technique. Further analyses investigated the effect of preoperative coronal alignment on trochlear position. Comparisons were assessed with an analysis of variance and Welch's t-tests or Wilcoxon's rank-sum tests with Bonferroni corrections. RESULTS: The implanted and simulated techniques all resulted in greater TA valgus compared to the native groove (p < 0.001). The implanted technique, KA and rKA were closer to the native TA than GB, MA and riKA (p > 0.001). All alignment philosophies understuffed the native trochlea groove. KA and rKA understuffed less than all other techniques (p < 0.001), and GB understuffed more than all other techniques (p < 0.001). In extension, all techniques shifted the trochlear sulcus laterally, while in flexion, they medialized it. These effects were most prominent in GB and MA. CONCLUSION: Personalized alignment techniques such as KA and rKA, which consider variations in individual anatomy, best restore the native patellar groove compared to systematic alignment techniques when using a standardized femoral component. LEVEL OF EVIDENCE: Level III, retrospective review.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/cirugía , Estudios Retrospectivos , Fémur/cirugía , Fenómenos Biomecánicos , Osteoartritis de la Rodilla/cirugía
18.
Knee Surg Sports Traumatol Arthrosc ; 32(4): 953-962, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38444096

RESUMEN

PURPOSE: The purpose of this study was to investigate the influence of increasing the tibial boundaries in functional alignment on femoral component orientation in total knee arthroplasty (TKA). METHODS: A retrospective review of a database of robotic-assisted TKAs using a digital joint tensioning device was performed (BalanceBot®; Corin). A total of 692 TKAs with correctable deformity were included. Functional alignment with a tibia-first balancing technique was simulated by performing an anatomic tibial resection to recreate the native medial proximal tibial angle within certain boundaries (A, 87-90°; B, 86-90°; C, 84-92°), while accounting for wear. After balancing the knee, the resulting amount of femoral component outliers in the coronal and axial plane was calculated for each group and correlated to the coronal plane alignment of the knee (CPAK) classification. RESULTS: The proportion of knees with high femoral component varus (>96°) or valgus (<87°) alignment increased from 24.5% (n = 170) in group A to 26.5% (n = 183) in group B and 34.2% (n = 237) in group C (p < 0.05). Similarly, more knees with high femoral component external rotation (>6°) or internal rotation (>3°) were identified in group C (33.4%, n = 231) than in group B (23.7%, n = 164) and A (18.4%, n = 127) (p < 0.05). There was a statistically significant (p < 0.01) overall increase in knees with both femoral component valgus <87° and internal rotation >3° from group A (4.0%, n = 28) to B (7.7%, n = 53) and C (15.8%, n = 109), with CPAK type I and II showing a 12.9- and 2.9-fold increase, respectively. CONCLUSION: Extending the tibial boundaries when using functional alignment with a tibia-first balancing technique in TKA leads to a statistically significant higher percentage of knees with a valgus lateral distal femoral angle < 87° and >3° internal rotation of the femoral component, especially in CPAK type I and II. LEVEL OF EVIDENCE: Level IV.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Tibia/cirugía , Articulación de la Rodilla/cirugía , Fémur/cirugía , Estudios Retrospectivos , Osteoartritis de la Rodilla/cirugía
19.
Knee Surg Sports Traumatol Arthrosc ; 32(4): 896-906, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38454836

RESUMEN

PURPOSE: Robotic arm-assisted total knee arthroplasty (RTKA) enables adjustment of implant position to achieve the surgeon's preferred alignment. However, the alignment concept that most effectively enhances patient satisfaction remains unclear. This study compares the clinical outcomes of patients who underwent functionally aligned RTKA (FA-RTKA), mechanically aligned conventional TKA (MA-CTKA) and mechanically aligned RTKA (MA-RTKA). METHODS: A prospectively collected database was retrospectively reviewed for patients who underwent primary TKA for knee osteoarthritis. One hundred and forty-seven knees were performed with MA-CTKA, followed by 72 consecutive knees performed with MA-RTKA, and subsequently, 70 consecutive knees performed with FA-RTKA were enrolled. After 1:1 propensity score matching of patient demographics, 70 knees were finally included in each group. The extent of additional soft tissue release during surgery was identified, and the Coronal Plane Alignment of the Knee classification was utilised to categorise the alignment. At the 1-year follow-up, patient-reported outcomes, including the pain Visual Analogue Scale, Knee Society Score, Western Ontario and McMaster Universities Arthritis Index and Forgotten Joint Score-12, were also compared among the groups. RESULTS: The FA-RTKA group showed significantly less additional soft tissue release than the MA-CTKA and MA-RTKA groups (15.7%, 38.6% and 35.7%, respectively; p = 0.006). Statistically significant differences in functional scores were observed in the postoperative 1-year clinical outcomes in favour of the FA-RTKA group, which had a significantly larger percentage of knees that maintained constitutional alignment and joint line obliquity than those of the other groups. CONCLUSIONS: Functionally aligned TKA showed superior 1-year postoperative patient-reported outcomes compared with those of conventional and robotic arm-assisted mechanically aligned TKA. Therefore, the advantage of RTKA is maximised when the implant positioning is based on functional alignment. The application of RTKA with mechanical alignment has been proven ineffective in improving the clinical outcomes of patients. LEVEL OF EVIDENCE: Level III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Procedimientos Quirúrgicos Robotizados , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Estudios Retrospectivos , Articulación de la Rodilla/cirugía , Medición de Resultados Informados por el Paciente
20.
Knee Surg Sports Traumatol Arthrosc ; 32(4): 941-952, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38461403

RESUMEN

PURPOSE: There have been insufficient data regarding the long-term results of unrestricted kinematically aligned total knee arthroplasty (unKATKA) in Asian patients. We investigated mid- to long-term clinical and radiological follow-up data of Korean patients after caliper-verified unKATKA of minimum 7.4-10 years including categorised data of postoperative tibial component, limb and knee alignment. Additionally, we analysed the preoperative distribution and postoperative restoration of coronal plane alignment of knee (CPAK) phenotypes. METHODS: This study is a retrospective analysis of 63 patients: 96 osteoarthritic underwent consecutive caliper-verified unKATKA between October 2013 and May 2016 by a single surgeon. Implant survivorship was investigated for revision for any reason. Each knee was categorised into an in-range or outlier group by three postoperative alignment parameters: tibial component, knee and limb alignment. Statistical analyses were done for any significant differences in clinical scores and implant survival rates between groups. Finally, all knees were classified into CPAK classification postoperatively and postoperatively. The CPAK restoration rate was calculated. RESULTS: Among 85 knees in the clinically confirmed group, implant survival was 98.8%. There was one case of revision due to periprosthetic fracture. The percentage postoperatively aligned in the varus (valgus) outlier range was 100% (0%) for tibial component, 16.7% (24.8%) for the knee alignment and 51% (0%) for the limb alignment. All three categories did not affect implant survival or clinical scores. Eighty one out of 96 knees (84.4%) were restored to their CPAK phenotype postoperatively. CONCLUSION: With the limitation of a case series having a small number of patients and gender deviation, our study suggests that caliper-verified unKATKA could be a good option regardless of geographical variation of constitutional alignment in patients with osteoarthritis (OA). LEVEL OF EVIDENCE: Level IV, therapeutic study.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Estudios Retrospectivos , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Tibia/cirugía , Fenómenos Biomecánicos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...